Products
Beijing Biotai Co., Ltd. and all staff are dedicate-d to providing customers with the best techni-cal solutions, quality products and after-sales services, and strive to promote the developme-nt of China's food safety industry.
TEL:400-1888-518
Evergreen Quinolone Test Kit
Quinolones are indicated for the treatment of community-acquired and nosocomial infections and are bactericidal. It is widely distributed throughout the body with higher tissue permeability than concentrations in plasma, feces, bile, prostate tissue and lung tissue. When the drug is metabolized by the kidneys, the drug penetrates the urine and kidneys. Quinolones have an antibacterial effect on many bacteria, especially gram-negative bacteria. Most side effects are gastrointestinal reactions (nausea, dyspepsia, and vomiting) and central nervous system reactions, such as dizziness, insomnia, and headache. The Biorex Quinolone Assay Kit uses the enzyme-linked immunosorbent principle to detect quinolones (fluoroquinolones) in a sample. Detection principle The kit uses enzyme-linked immunosorbent assay to detect quinolones. The microwells on the ELISA plate provided with the kit were pre-coated with quinolone antibody. A specific enzyme-linked reaction is performed by first adding the standard/sample and the enzyme label to the microwell. During incubation, the quinolones in the standard and sample compete with the enzyme label simultaneously for the limited binding sites on the coated antibody. The microwells are washed and the substrate reagent is added. Enzyme labeling and substrate blue color reaction, after incubation, adding stop solution to stop the reaction, the solution turned yellow. The corresponding absorbance values were read using a microplate reader at a wavelength of 450nm. The depth of color is inversely proportional to the quinolone content in the standard/sample, a standard curve is constructed, and the quinolone concentration in the sample is calculated. The kit consists of Chinese name, English name, specification, quinolone microplate Microtitreplate12 × 8 wells, coated with quinolone antibody standard Standards6 × 1.5ml, directly EnzymeConjugate amber bottle with enzyme marker concentrate, 100 μL/bottle high standard SpikingSolution1 × 1mL,100ng/mL washing concentrate WashSolution(50 ×)Concentrate 20mL ,50 × concentrated substrate solution SubstrateSolution amber plastic bottle, 1 × 14mL sample dilution concentrate SampleDiluent10X plastic bottle, blue lid, 2 × 25mL stop liquid StopSolution plastic bottle, red lid, 1 × 9mL microporous lid Platecover
Classification:
Evergreen Veterinary Drug Residues ELISA Kit
Key words:
Product number:
BXEFT10A
Specifications:
96 well
Product Description
Quinolones are indicated for the treatment of community-acquired and nosocomial infections and are bactericidal. It is widely distributed throughout the body with higher tissue permeability than concentrations in plasma, feces, bile, prostate tissue and lung tissue. When the drug is metabolized by the kidneys, the drug penetrates the urine and kidneys. Quinolones have an antibacterial effect on many bacteria, especially gram-negative bacteria. Most side effects are gastrointestinal reactions (nausea, dyspepsia, and vomiting) and central nervous system reactions, such as dizziness, insomnia, and headache.
EvergreenQuinolone detection kit uses the principle of enzyme-linked immunosorbent assay to detect quinolones (fluoroquinolones) in a sample.
Detection principle
The kit used enzyme-linked immunosorbent assay to detect quinolones. The microwells on the ELISA plate provided with the kit were pre-coated with quinolone antibody. First add the standard to the microwell/Samples and enzyme markers, specific enzyme-linked reaction. During incubation, the quinolones in the standard and sample compete with the enzyme label simultaneously for the limited binding sites on the coated antibody. The microwells are washed and the substrate reagent is added. Enzyme labeling and substrate blue color reaction, after incubation, adding stop solution to stop the reaction, the solution turned yellow. The corresponding absorbance values were read using a microplate reader at a wavelength of 450 nm. The depth of color is inversely proportional to the quinolone content in the standard/sample, a standard curve is constructed, and the quinolone concentration in the sample is calculated.
Kit composition
|
Chinese name |
English Name |
Specifications |
|
Quinolone microplate |
Flat Microtitre |
12 x 8 wells, coated with quinolone antibody |
|
Standard |
Standards |
6 × 1.5ml, Direct use |
|
Enzyme marker concentrate |
Enzyme Conjugate |
Amber bottle, 100 μL/bottle |
|
High Standard |
Spiking Solution |
1 × 1ml, 100ng/ml |
|
washing concentrate |
Wash Solution(50×)Concentrate |
20mL , 50 x concentrated |
|
Substrate solution |
Substrate Solution |
Amber plastic bottle, 1 x 14mL |
|
Sample Dilution Concentrate |
Sample Diluent 10X |
Plastic bottle, blue lid, 2 x 25mL |
|
Stop fluid |
Stop Solution |
Plastic bottle, red lid, 1 x 9mL |
|
microporous lid |
Plate cover |
|
Online Inquiry
recommend products
recommend products