Evergreen T2/HT2 Toxin Immunoaffinity Column

EvergreenT2/HT2 toxin toxin immunoaffinity column can purify T2/HT2 toxin in food and feed samples, and the purified samples can be used for HPLC analysis. Product performance measurement range:<1 μg T2/HT2 toxin. The detection limit is less than 1 ngT2/HT2 toxin. Recovery rate: when the content of T2/HT2 toxin in the sample is within the measurement range, the recovery rate of T2 toxin> 85% HT2 toxin> 85% cross-reacting T2 toxin: 85% HT2 toxin: 100 vomitoxin:<1% experimental principle immunoaffinity column can separate and purify T2/HT2 toxin from the sample matrix, and the content of T2/HT2 toxin can be determined by HPLC method. Due to the presence of interfering substances in some complex samples, the sensitivity of the determination of T2/HT2 toxins is low. The method combined with highly selective immunoaffinity column and HPLC column purification can accurately determine the T2/HT2 toxin in the sample. The maximum binding capacity of this immunoaffinity column was 500ng T2/HT2 toxin.

Classification:

Evergreen mycotoxin immunoaffinity column

Evergreen mycotoxins multi-function purification column

Key words:

Product number:

EB108303/EB108301

Specifications:

3ml/1ml

Online Inquiry

Product Description

Evergreen T2/HT2 toxin toxin immunoaffinity column can purify T2/HT2 toxin in food and feed samples, and the purified samples can be used for HPLC analysis.

Product Performance

Measurement range:<1 gT2/HT2 toxin. The detection limit is less than 1 ngT2/HT2 toxin.

Recovery:When in the sampleWhen the T2/HT2 toxin content is within the measurement range,

T2 toxin recovery> 85%

HT2 toxin recovery> 85%

cross reaction

T2 toxin: 85%

HT2 toxin: 100%

Vomiting toxin: <1%

Principle of Experiment

immunoaffinity column can be isolated and purified from sample matrixT2/HT2 toxin toxin, combined with HPLC method, can determine the content of T2/HT2 toxin.

Due to the presence of interfering substances in some complex samples, the determinationThe sensitivity of T2/HT2 toxin is lower. The method combined with highly selective immunoaffinity column and HPLC column purification can accurately determine the T2/HT2 toxin in the sample.

The maximum binding capacity of this immunoaffinity column is500 ngT2/HT2 toxin.