Products
Beijing Biotai Co., Ltd. and all staff are dedicate-d to providing customers with the best techni-cal solutions, quality products and after-sales services, and strive to promote the developme-nt of China's food safety industry.
TEL:400-1888-518
Evergreen Chloramphenicol Test Kit-Highly Sensitive
Chloramphenicol is associated with aplastic anemia in humans, can affect reproduction in animals, and is hepatotoxic. Chloramphenicol is a broad-spectrum antibiotic widely used in livestock and poultry breeding, which can kill the main gram-negative bacteria in animals. Many countries prohibit the use of chloramphenicol in food animals. Therefore, it is necessary to monitor chloramphenicol in foods such as meat, milk, honey and aquatic products. Biorex Chloramphenicol Detection Kit-highly sensitive detection of chloramphenicol in honey, muscle, eggs and seafood/shrimp using the principle of enzyme-linked immunosorbent assay. Detection principle The kit uses enzyme-linked immunosorbent assay to detect chloramphenicol. The micropores on the enzyme label plate provided by the kit are pre-coated with secondary antibodies. Standards or samples, enzyme labels and antibodies are added to the microwells. During incubation, the chloramphenicol in the standard/sample simultaneously competes with the enzyme label for the binding site on the antibody. Unbound enzyme-labeled conjugate is removed by washing. Then the substrate reagent is added, and the enzyme label reacts with the substrate. After incubation, the stop solution is added to terminate the reaction. The corresponding absorbance values were read using a microplate reader at a wavelength of 450nm. The depth of color is inversely proportional to the content in the standard/sample, a standard curve is constructed, and the concentration in the sample is calculated. The kit consists of Chinese name, English name, specification, microplate Microtitreplate12 × 8 wells, coated with secondary chloramphenicol standard Standards6 bottle, 1.5ml/bottle enzyme marker EnzymeConjugate 250μL/bottle, amber bottle enzyme marker diluent EnzymeConjugateDiluent1 × 12ml, red solution, plastic bottle antibody solution AntibodySolution1 × 12ml, blue solution, plastic bottle washing buffer (50 ×)WashSolution(50X)Concentrate1 × 20ml termination solution StopSolution1 × 9mL, red cap plastic bottle substrate solution SubstrateSolution1 ml × 24ml, amber plastic bottle sample diluent (5X)SampleDiluent5X2 ml × 25ml, blue cap plastic bottle high standard solution SpikingSolution1 ml × 1ml,100ng/ml microplate cap PLATECOVER cover microplate when incubated
Classification:
Evergreen Veterinary Drug Residues ELISA Kit
Key words:
Product number:
BXEFB06A
Specifications:
96 well
Product Description
Chloramphenicol is associated with aplastic anemia in humans, can affect reproduction in animals, and is hepatotoxic. Chloramphenicol is a broad-spectrum antibiotic widely used in livestock and poultry breeding, which can kill the main gram-negative bacteria in animals. Many countries prohibit the use of chloramphenicol in food animals. Therefore, it is necessary to monitor chloramphenicol in foods such as meat, milk, honey and aquatic products.
EvergreenChloramphenicol detection kit-highly sensitive detection of chloramphenicol in honey, muscle, eggs and seafood/shrimp using enzyme-linked immunosorbent principle.
Detection principle
The kit used enzyme-linked immunosorbent assay to detect chloramphenicol. The micropores on the enzyme label plate provided by the kit are pre-coated with secondary antibodies. Standards or samples, enzyme labels and antibodies are added to the microwells. During incubation, the standardThe chloramphenicol in the sample competes with the enzyme label simultaneously for the binding site on the antibody. Unbound enzyme-labeled conjugate is removed by washing. Then the substrate reagent is added, and the enzyme label reacts with the substrate. After incubation, the stop solution is added to terminate the reaction. The corresponding absorbance values were read using a microplate reader at a wavelength of 450 nm. The depth of color is inversely proportional to the content in the standard/sample, a standard curve is constructed, and the concentration in the sample is calculated.
Kit composition
|
Chinese name |
English Name |
Specifications |
|
Microplate |
Flat Microtitre |
12 × 8 wells, coated with secondary antibody |
|
Chloramphenicol Standard |
Standards |
6 bottles, 1.5ml/bottle |
|
enzyme marker |
Enzyme Conjugate |
250 μL/bottle, amber bottle |
|
enzyme marker dilution |
Enzyme Conjugate Diluent |
1 x 12ml, red solution, plastic bottle |
|
Antibody solution |
Antibody Solution |
1 x 12ml, blue solution, plastic bottle |
|
Wash buffer (50x) |
Wash Solution (50X) Concentrate |
1 × 20ml |
|
Stop fluid |
Stop Solution |
1 × 9mL, red cap plastic bottle |
|
Substrate solution |
Substrate Solution |
1 x 24ml, amber plastic bottle |
|
Sample Diluent (5X) |
Sample Diluent 5X |
2 x 25ml, blue cap plastic bottle |
|
high standard solution |
Spiking Solution |
1 × 1ml ,100ng/ml |
|
Microplate Cover |
PLATE COVER |
Cover microplate when incubating |
Online Inquiry
recommend products
recommend products